()Installations-Parameter Information (continued)




 

Parameter Description
EnHgKg 0 = / Comb-/skirt contacts not locked 1 = / Comb-/skirt contacts locked acc. Code-HK
Langua 0 = D 1 = DK 2 = NL 3 = GB 4 = F 5 = I 6 = P 7 = E 8 = S
Panel 1 32,33 = OPs address at upper landing 40 = CP s address at upper landing [#}
Panel2 0 = No panel at lower landing 41 = CPs address at lower landing[#]
EMS-ID 0 = No ERMS-2 1 - 255 = address of escalator to ERMS-2 [#]
ASNmin 17 - 38 Minimum voltage for missing phase detection
Value Switch off Phase Voltage (L-L) [V] Nominal Phase / Line Voltage (L-L / L-N) [V]
    200 / 115
    210 / 121
    220 / 127
    230 / 133
    350 / 202
    380 / 219
    400 / 231
    415 / 240
    440 / 254
    460 / 266
    480 / 277

 


1.36.4. / IO:-Parameters: (inputs): (< M > <1> < 3 > < 4>)

 

Feature Device Input IO# Disable [Addr.Pin] RS Enable [Addr.Pin]
Standard . Safety contacts RSFF Circuit Upper Landing FU1   - UL 05.1
Standard FU2   - UL 05.2
Standard FU3   - UL 05.3
Standard FU4   - UL 05.4
30FAULT . Safety contacts RSFF Circuit Lower Landing FL1   00.0 LL 06.1
30FAULT FL2   00.0 LL 06.2
30FAULT FL3   00.0 LL 06.3
30FAULT FL4   00.0 LL 06.4
BRAMO1 S33,34 MB lift switch BLS   00.0 - -
BRAMO2 S34 1 . MB lift switch 1 BLS 00.0   10.1
BLWD1 S31,32 MB wear c. BLW   00.0 - -
BLWD2 S31 MB wear contact BLW 00.0   10.4
BLWD2 S32 MB wear contact BL2   00.0   20.4
EB1, EB2 S53 EB-lift switch EB   01.0   11.4
EB1, EB2 K02 EB-Relay EBR   01.0 - -
OILLEV S44 OIL level switch OIL   01.0 - -
MSD B25 . Sensor upper l. IEU   01.0 - -
MSD B26 Sensor lower l. IED   01.0 - -
FPC S5 Contact upper l. UAC   01.0   11.1
FPC S6 Contact lower l. MAC   01.0   20.3
BRAMO2 S33 2 .MB lift switch 2 BR2   00.0   20.1
ARS S51 ARS Switch ARE   00.0 - -
ARS K10 (free) ARS free relay ARF   00.0 - -
ARS K10. 1 free delayed ARD   00.0 - -
TCU B3.1 . Sensor upper l. TCU   01.0 - -
HALT K087 Remote relay HLT   01.0 - -
CONINT Remote command CNT   00.0 - -
CONINT Remote command INT   00.0 - -
VF S70 VF-switch VFE   00.0 - -
VF VF Converter ok ( _ VFO   00.0 - -
VF K7 high speed VFH   00.0 - -
VF K6 low speed VFL   00.0 - -
HALT Stop upper . landing STU   01.0 - -
HALT Stop lower Stop . landing STL   01.0 - -
PDD 2- Select 2-way mode WAY   00.0 - -
PDD Disable 2-. way mode WON   00.0 - -
TCU Disable Zero-degree ZER   00.0 - -
FLOOD B17 Flooding FLD   00.0 - -
        00.0 - -
        00.0 - -
2ND Brake lift test monitor BLT   00.0   10.3
Not used     39 - 47 00.0 - -

1.46.5. /IO-Parameters: Outputs: (< M > <1> < 3 > < 4>)

Feature Device Output IO# Disable [Addr.Pin] RS Enable [Addr.Pin]
Standard : Safety circuit u. l. FF-Res   - UL 05.1
30FAULT -: Safety circuit l. l.. FF-Res   00.0 LL 06.1
Standard -: ..Safety circuit u. l. FF-Led ()   - UL 05.2
30FAULT -: .Safety circuit l. l. FF-Led   00.0 LL 06.2
TFL H40 Traf.light u. . . ..Green u.   00.0 - -
TFL H40 Traf ..light u. ..Red u.   00.0 - -
TFL H43 .Traf.light l. . Green l...   00.0 - -
TFL H43 Traf . ..light l. . ..Red l.   00.0 - -
LUB6 Y7 Lubr. pump Pump   00.0 - -
LUB6 Y8 : 2- Lubr 2nd valve Valve   00.0 - -
BUZZ H34/BZT . . .upper l. Buzzer   00.0   10.2
BUZZ H35/BZT . . .lower l. Buzzer   00.0   20.3
PFC X401 2 Fault   00.0   10.4
PFC X409 10 ESB   00.0   11.4
PFC X403 4 Up ()   00.0   11.1
PFC X405 6 Down (   00.0   11.2
PFC X407 8 Run ()   00.0   11.3
BRADEL K1 Up Contactor() UPCTL   00.0 - -
BRADEL K2 Down ()Contac DWNCTL   00.0 - -
BRADEL K032 Brake Relay BRKCTL   00.0 - -
ARS ECB-KSU1 IPUP1   00.0 - -
ARS ECB-KSD1 IPDWN1   00.0 - -
ARS ECB-KSU2 IPUP2   00.0 - -
ARS ECB-KSD2 IPDWN2   00.0 - -
PFC-ARS   IPSF   00.0 - -
PFC-INS   INS   00.0 - -
PFC-NOR   NORM   00.0 - -
SDL2   SDL   00.0 - -
VF VF VF-START   00.0 - -
VF K85 VF-SPEED   00.0 - -
VF VF VF-DWN   00.0 - -
VF K89 VF-INI   00.0 - -
FIL : Fault Indic. Light FIL   00.0 - -
PDD TFL 2- : TFL 2-way sign UL . Way u.   00.0 - -
PDD . TFL -. .: ..2-way sign LL Way l.   00.0 - -
PFC-INT X407 8 PFC-INT   00.0 - -
PFC-CONT X411 12 CONT   00.0 - -
PFC-WAY X413 14 WAY   00.0 - -
PFC-HALT X415 - 16 HALT   00.0 - -
2ND BLT-Enable PFC-BLT   00.0   10.3
        00.0 - -
        00.0 - -
OS RC3 RC3-RESET   00.0 - -
-Not used     91-95 00.0 - -

 





:


: 2016-12-05; !; : 337 |


:

: