Input signals description




Input Description
Off state ON state
NOR nor Inspection blind plugs
nrd NRD Non reversal device speed
res RES NRD reset button
pf PF electronic voltage

 

Input Description
Off state ON state
hrr HRR Sensor handrail right
hrl HRL Sensor handrail left
inr INR EN For contracts only
ANSI Sensor missing step part return line
tmo TMO Motor temperature

 

Input Description
Off state ON state
ksu KSU upKey switch up position (run/start) (/)
ksd KSD down (/) Key switch down position (run/start)
pdu PDU EN Sensor passenger detector upper landing
ANSI . Sensor missing step part upper landing
pdl PDL EN Sensor passenger detector lower landing
ANSI Sensor missing step part lower landing

 

Input Description
Off state ON state
up UP direction up
dwn DWN direction down
run RUN / Standstill/operation
ydi YDI Status relay start (wye/delta)

 

Input Description
Off state ON state
fu1 - fu4 FU1 - FU4 Failure bit - upper landing
fl1 - fl4 FL1 - FL4 Failure bit lower landing

 

Input Description
Off state ON state
br2 BR2 Machine brake- 2
bls BLS - Machine brake 1
blw BLW - Brake line wear 1
bl2 BL2 - Brake line wear 2

() Input signals description (continued)

Input Description
Off state ON state
eb EB Main drive shaft brake
EBR ebr Emergency brake relay (NAO=ON)
oil OIL Oil reservoir
fld for contracts only

 

Input Description
Off state ON state
ieu IEU Missing step sensor upper landing
iel IEL Missing step sensor lower landing
uac UAC Upper floor plate
mac MAC Lower floor plate

 

Input Description
Off state ON state
are ARE Restart (disabled S51 = OFF; enabled via S51 = ON)
arf ARF Step band (/occupied/free)
ard ARD Step band (/occupied/free)
blt BLT Brake lift test

 

Input Description
Off state ON state
tcu TCU Temperature at upper landing
hlt HLT Remote HALT command
cnt CNT Remote CONT command
int INT Remote INT command

 

Input Description
Off state ON state
vfe VFE VF (disabled S70 = OFF; enabled S70 = ON)
vfo VFO VF converter
vfh VFH High speed contactor
vfl VFL Low speed contactor

 

Input Description
Off state ON state
stu, stl, way, won For contracts only
zer, bhr, bho, cpr For contracts only
bhu, bhm, bhl, cph For contracts only
khl, kil, khu, kiu For contracts only
     

 

Input Description
Off state ON state
l1 - l3 L1 - L3 Main line voltage L1-L3
j J Phase sequence L1 L3

6.26.3. Installation Parameter (< M > <1> < 3 > < 1>)

 

Feature Parameter Description Disable Enable Min. Max. Default Actual
STAR-D YD-T -Star-Delta Start Time [s]            
INT INT-EN Select intermittent mode            
INT, ETA3 INT-LR Long run time in dir. [s] -          
INT INT-SR . . []Short run time opp. dir. [s]            
BRAMO1/2 BLS-EN Select brake monitoring            
PCO/PCO1 InpLev Select passenger detector            
NOTIS ErrDis . Select error display            
BUZZ BUZ-T Buzzer time [s]            
Standard ErrLog . Error logging condition            
ETA3 ETA-EN Select ETA mode            
ETA3 PRSMax Limit star to delta [#]            
ETA3 PRSMin . Limit delta to star [#]            
60Hz En60Hz Select 60 Hertz motor            
Standard(x) Speed Step speed [/cm/s] -          
HRS HRSFrq Nominalfrequency[*0,.1Hz]            
HRS HRSHys Allowed Variance [%]            
HRS HRSErr Number of stops till lock            
CODE-HK EnHgKg Select locked contacts            
Standard(x) Langua Select display language -          
OP/CP Panel1 Address of panel upper l.            
CP Panel2 Address of panel lower l.            
ERMS-2 EMS-ID ERMS address of esc [#]            
ASN ASNmin ASN minim. Voltage [*10 V]            

 






:


: 2016-12-05; !; : 381 |


:

:

.
==> ...