SimPowerSystems. , . .




SimPowerSystems , . .

Connectors , .

Electrical Sources .

Elements , , , , ..

Extra Library .

Machines .

Measurements .

Power Electronics (, ..).

Discrete System .

Powerqui .

 

Connector ,

Bus Bar -

:

:

. . . Ctrl+R .. . .

Ground

:

:

. .

 

L connector - L-

:

:

().

T connector - T-

:

:

.

Neutral -

:

:

.

(). . :

10 . Neutral .

 

SimPowerSystem

Electrical Sources

3-Phase Programmable Voltage Source -

:

:

, , , .

:

:

Positive-sequence: [Amplitude (Vrms Ph-Ph) Phase (degrees) Freq. (Hz)]

[ : [ () ()]]. .

Time variation of:

[ ]. , . :

None - ,

Amplitude - ,

Phase - ,

Frequency - .

Type of variation:

[ ]. . :

Step - ,

Ramp - ,

Modulation - ,

Table of time-amplitude pairs - - '-'.

Step magnitude:

[ ]. , . (..), - . - . , 0.5, , 0.5 . Variation timing.

Rate of change (value/s):

[ (/c)]. . . ./, - . / - /.

Amplitude of the modulation:

[ ]. . (..), - . - .

Frequency of the modulation (Hz):

[ ()].

Variation timing (s): [Start End]

[ [ ]]. . ( ).

Fundamental and/or Harmonic generation

[ / ].

A: [Order(n) Amplitude Phase(degrees) Seq(0, 1 or 2)]

[A: [ (n) () (0, 1 2)]]. : , ( ), , (0 - , 1 - , 2 - ). Positive-sequence .

B: [Order(n) Amplitude Phase(degrees) Seq(0, 1 or 2)].

[: [ (n) () (0, 1 2)]]. .

Harmonic timing (s): [Start End]

[ () [ ]]. .

( ).

:

, . 0.02 0.06 0.5 ..

 

 

 

3-Phase Source -

:

:

.

:

:

Phase-to-phase rms voltage (V):

[ ].

Phase angle of phase A (deg):

[ ()].

Frequency (Hz):

[ ()]. .

Internal connection:

[ ]. :

Y - ,

Yn - ,

Yg - .

Specify impedance using short-circuit level:

[ ]. .

Source resistance (Ohms):

[ ()].

Source inductance (H):

[ ()].

3-Phase short-circuit level at base voltage (VA):

[ ].

Base voltage (Vrms ph-ph):

[ ]. .

X/R ratio:

[ ].

:

,

Q - ,

U - .

:

,

k - X R ( X/R ratio).

:

, . Multimetr.

 

AC Current Source -

:

:

.

 

AC Voltage Source -

:

:

.

Controlled Current Source -

:

:

.

 

Controlled Voltage Source -

:

:

.

 

DC Voltage Source -

:

:
.

SimPowerSystem

Elements ,

 

3-Phase Dynamic Load

:

:

, , P Q . , .

 

3-Phase Mutual Inductance Z1-Z0

:

:

.

 

3-Phase Parallel RLC Branch - RLC-

:

:

, RLC-. 3-Phase Parallel RLC Branch. , . , , .

 

3-Phase Series RLC Load - RLC-

:

:

, RLC-. - . . .

 

3-Phase Series RLC Branch - RLC-

:

:

, RLC-. , . , , .

 

3-Phase Series RLC Load - RLC-

:

:

, RLC-. - . .

 

3-Phase Breaker -

:

:

. Breaker, .

:

:

Initial status of breakers:

[ ]. :

open - ,

closed - .

Switching of phase A:

[ A]. . Initial status of breakers.

Switching of phase B:

[ B]. . Initial status of breakers.

Switching of phase C:

[ C]. . Initial status of breakers.

Transition times (s):

[ ]. , .

Sample time of the internal timer Ts (s):

[ ].

External control of switching times:

[ ]. . , , .

Breaker resistance Ron(Ohm):

[ ()].

Initial state (0 for 'open', 1 for'closed'):

[ (0 - , 1 -)].

Snubber resistance Rs(Ohm):

[ ()].

Snubber capacitance Cs(F):

[ ()].

Measurements:

[ ]. :

None - ,

Branch voltage Voltage- ,

Branch current - ,

Branch voltage and current - .

 

3-Phase Fault -

:

:

, , . . Rg 106 , . .

3-Phase PI Section Line - .

:

:

. . .

Three-phase Linear Transformer (12-terminals) - (12-)

:

:
. . . .

Breaker -

:

:

. . . , . RC-, .

Distributed Parameters Line -

:

:

. .

Linear Transformer -

:

:

. . .

 

. . .

 

Mutual Inductance -

:

:

. - .

 

Parallel RLC Branch - RLC-

:

:

, .

.

 

Parallel RLC Load - RLC-

:

:

, . . .

 

PI Section Line -

:

:

. , , . . , . :

,

fmax - ,

- /c, / /,

l - ,

N - .

 

Saturable Transformer -

:

:

. . . .


Rm . Lsat .

- . . .

 

Series RLC Branch - RLC-

:

:

, . .

 

Series RLC Load - RLC-

:

:

, . . .

 

Surge Arrester -

:

:

() - . , () . :

 

Three-phase Transformer (Three Windings)-

:

:

. . .

:

:
Port configuration:
[ ]. ( ) . :

ABC as input terminals - (, B C) . (abc) .

ABC as output terminals - (, B C) . (abc) .

Nominal power and frequency [Pn(VA) fn(Hz)]:
[ () () ].
Winding 1 (ABC) connection:
[C ]. :

Y - ,

Yn - ,

Yg - ,

Delta(D1) - ,

Delta(D11) - .

Winding parameters [V1 Ph-Ph(V), R1(pu), L1(pu)]:
[ ]. (), (..), (..).
Winding 2 (abc) connection:
[C ]. :

Y ,

Yn ,

Yg ,

Delta(D1) ,

Delta(D11) .

Winding parameters [U2 Ph-Ph(V), R2(pu), L2(pu) ]:
[ ]. (), (..), (..).
Winding 3 (abc) connection:
[C ]. :

Y - ,

Yn - ,

Yg - ,

Delta(D1) - ,

Delta(D11) - .

Winding parameters [U3 Ph-Ph(V), R2(pu), L2(pu) ]:
[ ]. (), (..), (..).
Saturable core:
[ ]. .
Magnetization resistance Rm(pu):
[ (..)].
Magnetization inductance Lm(pu):

[ (..)]. ( Saturable core ).
Saturation characteristic (pu) [i1, phi1; i2, phi2;]
[ ]. . ( Saturable core ).
Simulate hysteresis:
[ ]. .

Hysteresis Data Mat file:
[ , ]. Powergui. Simulate hysteresis.
Specify initial fluxes [phi0A, phi0B, phi0C]:
[ ]. ( Saturable core ).

Measurements:

[ ]. :

Winding voltages - ,

Winding currents - ,

Flux and excitation current (Imag_IRm) - ,

Flux and magnetization current (Imag) - ,

All Measurements (V, I, Flux)- , .

,
.

Three-phase Transformer (Two Windings)-

:

:
. . .
:

:
Nominal power and frequency [Pn(VA) fn(Hz)]:
[ () () ].
Winding 1 (ABC) connection [Y, Yn, Yg, Delta(D1), Delta(D11)]:
[C ]. :

Y - ,

Yn - ,

Yg - ,

Delta(D1) - ( 300 . , ),

Delta(D11) - ( 300 . , ).

Winding 1 parameters [V1 Ph-Ph(V), R1(pu), L1(pu) ]
[ ]. (), (..), (..).
Winding 2 (abc) connection [Y, Yn, Yg, Delta(D1), Delta(D11)]
[C ]. :

Y - ,

Yn - ,

Yg - ,

Delta(D1) - ,

Delta(D11) - .

Winding 2 parameters [U2 Ph-Ph(V), R2(pu), L2(pu) ]:
[ ]. (), (..), (..).

Saturable core:
[ ]. .Magnetization resistance Rm(pu):
[C (..)].
Magnetization inductance Lm(pu):
[ (..)]. ( Saturable core ).
Saturation characteristic (pu) [i1, phi1; i2, phi2;]
[ ]. . ( Saturable core ).
Simulate hysteresis:
[ ]. .
Hysteresis Data Mat file:
[ , ]. Powergui.
Specify initial fluxes [phi0A, phi0B, phi0C]:
[ ]. ( Saturable core ).
Measurements:
[ ]. :

Winding voltages - ,

Winding currents - ,

Flux and excitation current (Imag_IRm) - ,

Flux and magnetization current (Imag) -,

All Measurements (V, I, Flux)- , .

, .
.

Zigzag Phase-Shifting Transformer -

:

:
, . . . .





:


: 2017-04-15; !; : 2148 |


:

:

, .
==> ...

1647 - | 1509 -


© 2015-2024 lektsii.org - -

: 0.191 .